SMART Evo, these are digital X-ray units that set standards for many years to come. A powerful computer with an intuitive user interface is the core of the EVO system management. It allows you to directly access both the main and additional functions, such as the calculation of exposure and exposure profiles, simplifies the management of diagnostics. The EVO Exposure Calculator built into the control panel performs a quick calculation and optimizes the exposure time to get quality results. A wide range of films, materials and other parameters are supported. Support is also provided for all types of film and digital image processing.

A wide range of accessories allows you to further improve the work. Tripods and other accessories are available that expand the capabilities of the devices for solving any control tasks.

 

More information: YXYLON SMART EVO

Main characteristics:

  • less weight
  • iso watt mode
  • beam of radiation 40 ° x60 °
  • degree of protection IP65
  • double casing radiator
  • extended climatic range
  • convenient for carrying and operating the control panel
  • Exposure Calculator
  • circular signal lamp emitter
  • built-in laser pointer of radiation edges
  • compatibility of service equipment and spare parts

X-ray units of the SMART Evo series meet high international safety standards, including element-by-element quality control. Digital X-ray units YXLON SMART EVO have focal spots from 1.0 mm to 3-0 mm and power from 750 8 tons to 900 8 tons, which makes them high-performance, reduces the exposure time and improves image quality.

Specifications EVO 160D
Weight 22 kg
Height 611 mm
The size of the focal spot on  en 12543 1.0 mm
High voltage 20 — 160 кV
Tube current 0.5 — 70 мА
Maximum capacity 750 W
Beam solution 40° х 60°
Scattered radiation Max. 2.0 mSy/h
Protection class IP65
Operating temperature range -20°C to +50°C
Exposure at  35°C with max kV, max ma min. 1 hour

 

Specifications EVO 200D
Weight 23 kg
Height 635 mm
The size of the focal spot on  en 12543 1.0 mm
High voltage 30 — 200 кV
Tube current 0.5 — 6.0 мА
Maximum capacity 750 W
Beam solution 40° х 60°
Scattered radiation Max. 2.0 mSy/h
Protection class IP65
Operating temperature range -20°C to +50°C
Exposure at  35°C with max kV, max ma min. 1 hour

 

Specifications EVO 225D
Weight 26 kg
Height 708 mm
The size of the focal spot on  en 12543 3.0 mm
High voltage 40 — 225 кV
Tube current 0.5 — 5.5 мА
Maximum capacity 900 W
Beam solution 40° х 60°
Scattered radiation Max. 5.0 mSy/h
Protection class IP65
Operating temperature range -20°C to +50°C
Exposure at  35°C with max kV, max ma min. 1 hour

Specifications EVO 300D
Weight 29 kg
Height 774 mm
The size of the focal spot on  en 12543 3.0 mm
High voltage 50 — 300 кV
Tube current 0.5 — 4.5 мА
Maximum capacity 900 W
Beam solution 40° х 60°
Scattered radiation Max. 5.0 mSy/h
Protection class IP65
Operating temperature range -20°C to +50°C
Exposure at  35°C with max kV, max ma min. 1 hour

POWER SUPPLY

Differential voltages from 85 to 264 VAC with a frequency of 45 to 65 Hz, subject to local standards, are allowed. An improved voltage regulator ensures uninterrupted operation of the device in difficult conditions.

COMPLIANCE WITH CERTIFICATES

CE (Low voltage EN 61010-1, EMC 2004/108 / EC, Machinery EN 60204-1). OIN 54113 and Rôntgenverordnung (RôV).

Portable X-ray units of the SMART Evo series